OPERATION OF THE TRIODE
FACTORS AFFECTING TRIODE OPERATION

Neets Module 06-Introduction to Electronic Emission, Tubes, and Power Supplies
Page Navigation
  21    22    23    24    25  26  27    28    29    30    31  
1-26 Simply, quiescent describes circuit conditions when the tube is not amplifying. The tube has no output signal and is in a kind of standby, waiting condition. Now let’s go on to figure 1-19. With no input signal, under quiescent conditions, assume that 1 milliampere of current flows through the tube, cathode to plate. This current (Ip) will flow through RL (load resistor) to the positive terminal of the battery. The current flowing through RL  causes a voltage drop (IR) across RL equal to: Subtracting the voltage dropped across the plate-load resistor from the source voltage of 300 volts gives you 200 volts (300 volts - 100 volts). Thus, the plate voltage (Ep) is at 200 volts. The quiescent conditions for the circuit are: These values are shown on the waveforms as time a in figure 1-19. You should notice that even though the grid is more negative (-6 volts) than the cathode, the tube in the circuit is still conducting, but not as heavily as it would if the grid were at zero volts. Now look at the input signal from the transformer secondary. For ease of explanation, we will consider only three points of the ac sine wave input: point b, the maximum negative excursion; point c, the maximum positive excursion; and point d, the zero reference or null point of the signal. At time b, the input signal at the grid will be at its most negative value (-3 volts). This will cause the grid to go to -9 volts (-6 volts + -3 volts). This is shown at time b on the grid voltage waveform. The increased negative voltage on the control grid will decrease the electrostatic attraction between the plate and the cathode. Conduction through the tube (Ip) will decrease. Assume that it drops to .5 milliamperes. The decrease in plate current will cause the voltage drop across the plate-load resistor (RL) to also decrease from 100 volts, as explained by Ohm’s law: Plate voltage will then rise +250 volts. This is shown on the output signal waveform at time b. At time c, the input has reached its maximum positive value of +3 volts. This will decrease grid voltage to -3 volts (-6 volts + 3 volts). This is shown on the grid voltage waveform at time c. This in turn will increase the electrostatic force between the plate and cathode. More electrons will then flow from the






Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.