• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
SUMMARY - 14188_108
ANSWERS TO QUESTIONS Q1. THROUGH Q29. - 14188_110

Neets Module 16-Introduction to Test Equipment
Page Navigation
  88    89    90    91    92  93  94    95    96    97    98  
3-33 A CONTINUITY TEST is accomplished with an ohmmeter. This test is used to check for opens (or to see if the circuit is complete or continuous). GROUNDED CIRCUITS are caused by some conducting part of the circuit making contact either directly or indirectly with the metallic structure of the ship or chassis. In testing for grounds, you may use either an ohmmeter or a megger. A SHORT CIRCUIT, other than a grounded one, is where two conductors touch each other directly or through another conducting element. An ohmmeter is used to test for shorts. ANSWERS TO QUESTIONS Q1. THROUGH Q29. A-1.   Self-excited. A-2.   Phosphor bronze ribbons. A-3.   The pointer arrangement and the light and mirror arrangement. A-4.   Coil balance. A-5.   Hairspring. A-6.   Hairspring. A-7.   Makes it possible to have a more linear scale than if the poles were flat. A-8.   Shunt. A-9.   Zero-temperature coefficient. A-10.   Midscale. A-11.   In series. A-12.   Negative, positive.






Western Governors University

Privacy Statement